400 V Class
200 V Class
Note: Models of 18.5 to 110 kW are equipped with built-in DC reactor to improve power factor.
Motor
Capacity
(kW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV63-SV
NV63-SV
NV125-SV
NV125-SV
Model
Without Reactor
*1
Ground Fault Interrupter (GFI)
With Reactor
*2
5
10
15
20
30
50
60
75
125
Rated
Current
(A)
10/10
10/10
10/10
10/10
10/10
15/15
15/15
50/50
50/50
Rated breaking
capacity (kA)
Icu/Ics
*3
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV63-SV
NV63-SV
NV125-SV
NV125-SV
NV250-SV
NV250-SV
NV250-SV
NV250-SV
NV400-SW
NV400-SW
NV400-SW
NV630-SW
NV630-SW
Model
5
10
10
15
20
40
50
75
100
125
150
175
225
250
300
400
500
600
Rated
Current
(A)
10/10
10/10
10/10
10/10
10/10
15/15
15/15
50/50
50/50
85/85
85/85
85/85
85/85
42/42
42/42
42/42
42/42
42/42
Rated breaking
capacity (kA)
Icu/Ics
*3
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF63-SV
NF125-SV
NF125-SV
NF250-SV
Model
Without Reactor
*1
Circuit Breaker
With Reactor
*2
5
10
15
20
30
50
60
75
125
Rated
Current
(A)
7.5/7.5
7.5/7.5
7.5/7.5
7.5/7.5
7.5/7.5
15/15
50/50
50/50
85/85
Rated breaking
capacity (kA)
Icu/Ics
*3
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF63-SV
NF63-SV
NF125-SV
NF125-SV
NF250-SV
NF250-SV
NF250-SV
NF250-SV
NF400-CW
NF400-CW
NF400-CW
NF630-CW
NF630-CW
Model
5
10
10
15
20
40
50
75
100
125
150
175
225
250
300
400
500
600
Rated
Current
(A)
7.5/7.5
7.5/7.5
7.5/7.5
7.5/7.5
7.5/7.5
15/15
15/15
50/50
50/50
85/85
85/85
85/85
85/85
50/25
50/25
50/25
50/25
50/25
Rated breaking
capacity (kA)
Icu/Ics
*3
Motor
Capacity
(kW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
185
220
300
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV63-SV
NV125-SV
Model
Without Reactor
*1
Ground Fault Interrupter(GFI)
With Reactor
*2
3
5
10
15
20
30
30
50
60
Rated
Current
(A)
5/5
5/5
5/5
5/5
5/5
5/5
5/5
7.5/7.5
25/25
Rated breaking
capacity (kA)
Icu/Ics
*3
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV32-SV
NV63-SV
NV63-SV
NV125-SV
NV125-SV
NV125-SV
NV250-SV
NV250-SV
NV250-SV
NV250-SV
NV400-SW
NV400-SW
NV400-SW
NV400-SW
NV630-SW
NV630-SW
NV800-SEW
Model
3
5
10
10
15
20
30
40
50
60
75
100
125
150
175
225
250
300
350
400
500
630
800
Rated
Current
(A)
5/5
5/5
5/5
5/5
5/5
5/5
5/5
7.5/7.5
7.5/7.5
25/25
25/25
25/25
36/36
36/36
36/36
36/36
42/42
42/42
42/42
42/42
42/42
42/42
42/42
Rated breaking
capacity (kA)
Icu/Ics
*3
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF63-SV
NF125-SV
Model
Without Reactor
*1
Circuit Breaker
With Reactor
*2
3
5
10
15
20
30
30
50
60
Rated
Current
(A)
2.5/2.5
2.5/2.5
2.5/2.5
2.5/2.5
2.5/2.5
2.5/2.5
2.5/2.5
7.5/7.5
18/18
Rated breaking
capacity (kA)
Icu/Ics
*3
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF32-SV
NF63-SV
NF63-SV
NF125-SV
NF125-SV
NF125-SV
NF250-SV
NF250-SV
NF250-SV
NF250-SV
NF400-CW
NF400-CW
NF400-CW
NF400-CW
NF630-CW
NF630-CW
NF800-CEW
Model
3
5
10
10
15
20
30
40
50
60
75
100
125
150
175
225
250
300
350
400
500
630
800
Rated
Current
(A)
2.5/2.5
2.5/2.5
2.5/2.5
2.5/2.5
2.5/2.5
2.5/2.5
2.5/2.5
7.5/7.5
7.5/7.5
25/25
25/25
25/25
36/36
36/36
36/36
36/36
25/13
25/13
25/13
25/13
36/18
36/18
36/18
Rated breaking
capacity (kA)
Icu/Ics
*3
*1:
*2:
*3:
The AC or DC reactor is not connected to the drive.
The AC or DC reactor is connected to the drive.
Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity
Note: Models of 18.5 to 110 kW are equipped with built-in DC reactor to improve power factor.
*1:
*2:
*3:
The AC or DC reactor is not connected to the drive.
The AC or DC reactor is connected to the drive.
Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity
Options, Peripheral Devices
Ground Fault Interrupter (GFI),
Circuit Breaker (MCCB)
Be sure to connect an MCCB or ground fault interrupter
between the power supply and Varispeed G7 input terminals
R, S, T.
Ground Fault Interrupter
(
GFI
)
[
Mitsubishi Electric Corporation
]
Circuit Breaker
[
Mitsubishi Electric Corporation
]
Vue de la page 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 102 103

Commentaires sur ces manuels

Pas de commentaire