YASKAWA NX100 Spécifications Page 51

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 186
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 50
52/201
BscGetStatus
FUNCTION: Reads the status information.
FORMAT: _declspec( dllexport ) short APIENTRY BscGetStatus(short nCid,short
*d1,short *d2)
ARGUMENTS: IN(Transfer)
nCid Communication handler ID number
*d1 Data 1 storage pointer
*d2 Data 2 storage pointer
OUT(Return)
*d1 Data 1 storage pointer
*d2 Data 2 storage pointer
Return Value
-1:Fetch failed
Others:Normal completion
REMARKS: Data 1
Data 1 are represented by bit data in decimals.
D7 D6 D5 D4 D3 D2 D1 D0
StepOperation at safe speed
D1:1-cycle Teach *
Auto operationPlay *
OperatingCommand remote *
*: Effective only for NX100, XRC and MRC.
Data 2
Data 2 are represented by bit data in decimals.
D7 D6 D5 D4 D3 D2 D1 D0
D0:Hold (NX100/XRC/MRC: Playback box hold, ERC:Panel hold)
D1:Hold (NX100/XRC/MRC: Programming pendant hold, ERC: T-BOX hold)
D2:Hold (External hold)
D3:Hold(Command hold)
D4:Alarm occurred
D5:Error occurred
Servo ON
Vue de la page 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 185 186

Commentaires sur ces manuels

Pas de commentaire