Determines whether output frequency or output current is indicated on the analog
output terminals, AM-AC, for monitoring.
Initial setting-analog voltage of approx. 10V is output when output frequency (output
current) is 100%.
Used to adjust analog output gain.
Scales the analog output voltage signal level at 100% of output frequency (output
current).
Example: Frequency meter displays 0 to 60Hz with 0 to 3V.
10V x n45 setting (0.30V) = 3V (3V is output at 100% output frequency)
Using a frequency meter or ammeter (n44)
Setting Description
0 Output frequency
1 Output current
Calibrating frequency meter or ammeter (n045)