48
Operation Example Chapter 4-2
4-2-6 Actual Load Operation
After checking the operation with the motor in no-load status, connect the
mechanical system and operate with an actual load.
Note Before operating the Digital Operator, check that the FREQ adjuster is set to
MIN.
Connecting the System
After confirming that the motor has stopped completely, connect the
mechanical system.
Be sure to tighten all the screws when fixing the motor axis in the
mechanical system.
Operation Using the Digital Operator
• In case a fault occurs during operation, make sure the Stop Key on the
Digital Operator is easily accessible.
Use the Digital Operator in the same way as no-load operation.
First set the frequency reference to a low speed of one tenth the normal
operating speed.
Checking the Operating Status
Having checked that the operating direction is correct and that the
machine is operating smoothly at slow speed, increase the frequency
reference.
After changing the frequency reference or the rotation direction, check
that there is no vibration or abnormal sound from the motor. Check the
monitor display (IOUT or multi-function monitor U03) to ensure that the
output current is not becoming excessive.