8.7 QUEUE TABLE READ Instructions (QTBLR,QTBLRI)
8-15
[Parameter]
Parameter Name Setting
Table Name Table name
Read Data · Register address (except for # and C registers)
· Register address with subscript
Parameter · Register address
· Register address with subscript
[Output] · Any integer type register (except for # and C registers)
· Any integer type register with subscript
· Subscript register
* possible to omit
[Status] · Any bit type register (except for # and C registers)
· Any bit type register with subscript
* possible to omit
[Program Example]
Column element data (element format assumed to be integer) from the table defined as TABLE1 is
stored for the number of column elements beginning with MW00100 using DW00010 to DW00012 as
a parameter table.