2.17 ABSOLUTE VALUE CONVERSION Instruction (ABS)
2-29
2.17 ABSOLUTE VALUE CONVERSION Instruction (ABS)
[Outline]
The ABS instruction determines the absolute value of the contents of the Source and the result is
stored in the Dest.
[Format]
Symbol : ABS
Full Name : Absolute
Category : MATH
Icon :
[Parameter]
Parameter Name Setting
Source · Any integer type, double-length integer type and real number type register
· Any integer type, double-length integer type and real number type register
with subscript
· Subscript register
Dest · Any integer type, double-length integer type and real number type register
(except for # and C registers)
· Any integer type, double-length integer type and real number type register
with subscript (except for # and C registers)
· Subscript register