Yaskawa Microtrac Gateway to Square D Sy/MAX Family of PLC Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Yaskawa Microtrac Gateway to Square D Sy/MAX Family of PLC. Yaskawa Microtrac Gateway to Square D Sy/MAX Family of PLCs for use with Microtrac LAN User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 13
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
4/12/94
Warranty Standard products manufactured by the Company are warranted to be free from defects in
workmanship and material for a period of one year from date of shipment and any products which are
defective in workmanship or material will be repaired or replaced, at the Company's option, at no charge to
the Buyer. Final determination as to whether a product is actually defective rests with the Company. The
obligation of the Company hereunder shall be limited solely to repair or replace, at the Company's
discretion, products that fall within the foregoing limitations, and shall be conditioned upon receipt by the
Company or written notice of any alleged defects or deficiency promptly after discovery and within the
warranty period, and in the case of components or units purchased by the Company, the obligations of the
Company shall not exceed the settlement that the Company is able to obtain from the supplier thereof. No
products shall be returned to the Company without its prior consent. Products which the Company
consents to have returned shall be shipped prepaid f.o.b. the Company's factory. The Company cannot
assume responsibility or accept invoices for unauthorized repairs to its components, even though
defective. The life of the products of the Company depends, to a large extent, upon the usage thereof, and
THE COMPANY MAKES NO WARRANTY AS TO FITNESS OF ITS PRODUCTS FOR THE
SPECIFIC APPLICATIONS BY THE BUYER NOR AS TO PERIOD OF SERVICE UNLESS THE
C O M PANY SPECIFICALLY AGREES OTHERWISE IN WRITING AFTER THE PROPOSED USAGE
HAS BEEN MADE KNOWN TO IT.
This warranty does not apply to experimental or developmental products for which NO warranty is made
or given and Buyer waives any claim thereto.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WA R R A N T I E S ,
EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF
M E R C H A N TABILITY OR OF FITNESS FOR A PA RTICULAR PURPOSE AND BUYER HEREBY
WAIVES ANY AND ALL CLAIMS THEREFORE.
Limitation Of Liability IN NO EVENT SHALL THE COMPANY BE LIABLE FOR LOSS OF
P R O F I T, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES WHETHER ARISING OUT
OF WA R R A N T Y, BREACH OF CONTRACT OR TO RT.
MicroTrac Gateway to
Square D Sy/MAX Family of PLC’s
Part No. 46S02914-0010
For use on MicroTrac Local Area Network
RD 914-10
Vue de la page 0
1 2 3 4 5 6 ... 12 13

Résumé du contenu

Page 1 - MicroTrac Gateway to

14/12/94Warranty Standard products manufactured by the Company are warranted to be free from defects inworkmanship and material for a period of one

Page 2 - S E T U P

104/12/944OPERATIONRemote Display Controller Input (RDCI) and Get Numeric (GETN)The input channel number will be in decimal notation. The associatedi

Page 3 - UP UP DN DN UP DN DN DN

114/12/944OPERATIONPower-upGeneralWithin the PAC program, the RDU and PLC initialization tables are used toconfigure the multiple source parameter exc

Page 4 - S O F T WA R E

124/12/944OPERATIONSuggested PLC Ladder Strategy for GETN and RDCI PAC BlocksRung #LOAD_PLCLOAD_PLCLLLLLLTMRLOAD LATCH2 SECONDHANDSHAKETIMEOUTLOADUNLA

Page 5

134/12/944OPERATIONPLC Gateway StatusSince the 2’s complement number put into the appropriate register will be aninteger, not an integer plus fraction

Page 6 - Logic (I/O) Data

1Introduction1INTRODUCTION4/12/94I N T R O D U C T I O NS E T U PThe Square D Programmable Logic Controller Gateway (PLC Gateway) allowsany drive on t

Page 7

34/12/942SETUPThe ARCNET node ID is set using the 8-position DIP switch, SW1. Enter thebinary node ID by choosing either a "0" or "1&q

Page 8 - Numeric (I/O)

44/12/942SETUPSOFTWARE3. 80188 Based CPU card (MagneTek part no. 46S03016-0010).Set serial port select to RS-232 by installing jumper plug on E1 fro

Page 9

54/12/944OPERATIONOPERATION5/2/95The ARCNET node number, as set on the MicroTrac Network Interface cardand referenced by the various PAC blocks, will

Page 10

6PAC output channels numbered 1 to 255 to the “interfaced” PLC registersnumbered from 3501 to 3755).The PLC gateway does not allow the mixing of data

Page 11

74/12/944OPERATIONLogic (I/O) DataThe subchannel number will also be in decimal, and will directly correspond tothe bit number of the PLC input. Thus

Page 12 - RD 914-10

84/12/944OPERATIONNumeric (I/O) DataNumeric (I/O)DataThe subchannel number also will be in decimal, and will directly correspond tothe bit number of t

Page 13 - PLC Gateway

94/12/944OPERATIONRemote Display Controller Input (RDCI) and Get Numeric (GETN)Numeric Inputs (NUMI) to a PAC schematic from a PLC is illustrated inFi