Selects processing when STOP key is pressed during operation from multi-
function input terminal.
Operator stop key selection (n06)
Setting
Description
Setting
Description
0
STOP key ineffective when running either from multi-function input
terminals or communications.
1
STOP key effective when running either from multi-function input terminals
or communications. When STOP key is pressed, the inverter stops
according to the setting of constant n04. At this time, the digital operator
displays S P alarm (blinking). This stop command is held in the
inverter until both forward and reverse run commands are open, or
unitl run command from communications becomes zero.