62
Building Interface Circuits with External Devices
Multi-function input terminal S2 to S5 functions can be changed when
necessary by setting constants n36 to n39 respectively. The same value
cannot be set to different constant settings.
* Numbers 2 to 5 is displayed in corresponding to the terminal numbers S2 to S5 respectively.
Using input signals
Setting Name Description Ref.
0
2
3
4
5
6
7
8
10
11
12
13
14
15
16
17
18
19
20
21
22
34
35
FWD/REV run command
(3-wire sequence selection)
Reverse run
(2-wire sequence selection)
External fault (NC contact input)
Fault reset
Multi-step speed reference 1
Multi-step speed reference 2
Multi-step speed reference 3
External fault (NO contact input)
JOG command
Accel/decel time select
External baseblock
(NO contact input)
External baseblock
(NC contact input)
Search command from
maximum frequency
Search command from
set frequency
Accel/decel hold command
LOCAL/REMOTE selection
Communication/ control circuit
terminal selection
Emergency stop fault
(NO contact input)
Emergency stop alarm
(NO contact input)
Emergency stop fault
(NC contact input)
Emergency stop alarm
(NC contact input)
UP/DOWN command
Self-test
Setting enabled only for n37
Inverter stops by external fault
signal input.
Digital operator display is
?*.
Resets the fault. Fault reset not
effective with the run signal ON.
Setting enabled only for
n39 (terminal S5)
Setting enabled only for
n39 (terminal S5)
Speed search
reference signal
63
41
-
-
43
43
43
43
44
47
-
-
54
54
55
40
65
-
-
-
-
63
-
Motor coast to a stop by this
signal input.
Digital operator display is
BB.
Inverter stops by emergency stop signal input
according to stopping method selection (n04).
When frequency coasting to a stop (n04 is set
to 1) method is selected, inverter coasts to a
stop according to decel time setting 2 (n19).
Digital operator display is S P.
(lit at fault, blinking at alarm)
Function
No.
n36
n37
n38
n39
Terminal
S2
S3
S4
S5
Initial Setting
2
5
3
6
Reverse run (2-wire sequence selection)
External fault
(NO contact input)
Fault reset
Multi-step speed reference 1
Initial setting