1. Removal
(1) Remove the front cover and
terminal cover, and then remove
the cooling fan connector
(CN10).
(2) Press the right and left clicks of
the fan cover to direction 1, and
pull the fan cover to direction 2
to remove it from the inverter
unit. Pull out the wiring from the
cable lead-in hole at the bottom
of the plastic case.
(3) Open the right and left sides of
the fan cover to remove the
cover from the cooling fan.
2. Mounting
(1) Mount the cooling fan on the fan
cover. The arrow mark to
indicate the wind direction must
be opposite to the cover.
(2) Mount the fan cover on the
inverter. Be sure to mount the
right and left clicks of the fan
cover on the heatsink. Lead in
the wiring from the cable lead-in
hole at the bottom of the plastic
case to the inside of the inverter.
(3) Connect the wiring to the cooling
fan connector (CN10) and mount
the front cover and the terminal
cover.
Inverter of W-dimension (width) 108mm (4.25 inches)
COOLING
FAN WIRE
WIND DIRECTION