YASKAWA VS-606V7 Series Manuel d'instructions Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 176
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
30
Open the front cover and verify that the strip length is 5.5mm (0.22in.).
Wiring Inspection
After completing wiring, check the following :
Wiring is proper.
Wire clippings or screws are not left in the unit.
Screws are securely tightened.
Bare wire in the terminal does not contact other terminals.
If the FWD (REV) run command is given during the run command selection
(n003=1) from the control circuit terminal, the motor will start automatically
after the main circuit input power supply is turned ON.
NOTE
S5
MA MB MC
S6 S7 P1 P2
CONTACT OUTPUT
R R
FS FR FC
S2S1 S3 S4 SC PC
SW1 SW2
SS
AM
AC RP
SCALE
5.5
mm