6.1 Inspection
Power electronics have limited life and may exhibit changes in characteristics or performance deterioration after years of use
under normal conditions. To help avoid such problems, it is important to perform preventive maintenance and periodic
inspection on the drive.
Drives contain a variety of power electronics such as power transistors, semiconductors, capacitors, resistors, fans, and relays.
The electronics in the drive serve a critical role in maintaining proper motor control.
Follow the inspection lists provided in this chapter as a part of a regular maintenance program.
Note: The drive will require more frequent inspection if it is placed in harsh environments, such as:
High ambient temperatures
Frequent starting and stopping
Fluctuations in the AC supply or load
Excessive vibrations or shock loading
Dust, metal dust, salt, sulfuric acid, chlorine atmospheres
Poor storage conditions.
Perform the first equipment inspection one to two years after installation.
u
Recommended Periodic Inspection
outlines the recommended periodic inspections for Yaskawa drive installations. Although periodic inspections should generally
be performed once a year; the drive may require more frequent inspection in harsh environments or with rigorous use. Operating
and environmental conditions, along with experience in each application, will determine the actual inspection frequency for
each installation. Periodic inspection will help to avoid premature deterioration in performance or product failure. Copy this
checklist and mark the “Checked” column after each inspection.
n
Periodic Inspection
WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious
personal injury. Before servicing the drive, disconnect all power to the equipment. The internal capacitor remains charged even after the
power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock,
wait at least five minutes after all indicators are OFF and measure the DC bus voltage level to confirm safe level.
Table 6.1 Periodic Inspection Checklist
Inspection Area Inspection Points Corrective Action Checked
Main Circuit Periodic Inspection
General
Overall check of the main power circuit and
ground terminals
Take appropriate actions (e.g., tightening loose
connections).
Inspect equipment for discoloration from
overheating or deterioration.
Inspect for damaged or deformed parts.
Replace damaged components as required.
The drive has few serviceable parts and may require
complete drive replacement.
Inspect for dirt, foreign particles, or dust collection
on components.
Inspect enclosure door seal if present. Replace
components if cleaning is not possible.
Remove foreign particles and dust with a vacuum cleaner
to avoid touching parts.
Conductors and
Wiring
Inspect wiring and connections for discoloration,
damage, or heat stress.
Inspect wire insulation and shielding for wear.
Repair or replace damaged wiring.
Terminals
Inspect terminals for stripped, damaged, or loose
connections.
Tighten loose screws and replace damaged screws or
terminals.
Relays and
Contactors
Inspect contactors and relays for excessive noise
during operation.
Inspect coils for signs of overheating such as
melted or cracked insulation.
Check coil voltage for over or under voltage conditions.
Replace damaged removable relays contactors or circuit
board.
Braking Resistors
Inspect for discoloration of heat stress on or around
resistors.
Minor discoloration may be acceptable.
If discoloration exists check for loose connections.
Motor Periodic Inspection
Operation Check Check for increased vibration or abnormal noise.
Stop the motor and contact qualified maintenance
personnel as required.