4.4 MP2000 Series Machine Controller Parameter Details
4.4.2 Motion Setting Parameter Details
4-57
Motion Parameters
( 32 ) Absolute Infinite Length Axis Position Control Information
( 33 ) Command Buffer for Servo Driver Transmission Reference Mode
OL5E
Encoder Position when Power is OFF
(Lower 2 words)
Setting Range Setting Unit Default Value
-2
31
to 2
31
1
pulse 0
Description
This is the information for infinite length axis position control when an absolute encoder is used.
The encoder position is stored in 4 words.
If the Request ABS Rotary Pos LOAD bit is set to 1 in the RUN Command Setting (setting parameter OW00, bit 7),
the position information will be recalculated with the values set here and the Pulse Position when Power is OFF
(OL62 and OL64).
Refer to 9.4 Absolute Position Detection for Infinite Length Axes for details.
Set to 0 for linear type.
OL60
Encoder Position when Power is OFF
(Upper 2 words)
Setting Range Setting Unit Default Value
-2
31
to 2
31
1
pulse 0
Description
Same as for OL5E.
Refer to 9.4 Absolute Position Detection for Infinite Length Axes for details.
Set to 0 for linear type.
OL62
Pulse Position When Power is OFF (Lower 2 words)
Setting Range Setting Unit Default Value
-2
31
to 2
31
1
pulse 0
Description
This is the information for infinite length axis position control when an absolute encoder is used.
The axis position in pulses managed internally by the controller is stored in 4 words.
If the Request ABS Rotary Pos. LOAD bit is set to 1 in the Run Command Setting (setting parameter OW00, bit 7),
the position information will be recalculated with the values set here and the Encoder Position when Power is OFF
(OL5E and OL60).
Refer to 9.4 Absolute Position Detection for Infinite Length Axes for details.
Set to 0 for linear type.
OL64
Pulse Position When Power is OFF (Upper 2 words)
Setting Range Setting Unit Default Value
-2
31
to 2
31
1
pulse 0
Description
Same as for OL62.
Refer to 9.4 Absolute Position Detection for Infinite Length Axes for details.
Set to 0 for linear type.
OW70 to OW7E
Command Buffer for Servo Driver Transmission
Reference Mode
Setting Range Setting Unit Default Value
−−0
Description
This area is used for response data when MECHATROLINK Servo commands are specified directly.
MECHATROLINK-I and MECHATROLINK-II, 17-byte Mode: Data area = OW70 to OW77
MECHATROLINK- II, 32-byte Mode: Data area = OW70 to OW7E
Position
Phase
Speed
Torque
Position
Phase
Speed
Torque
Position
Phase
Speed
Torque
Position
Phase
Speed
Torque
Position
Phase
Speed
Torque