4.3 Motion Parameter Lists
4.3.2 Setting Parameter List
4-9
Motion Parameters
OW03
Function Setting 1
Bits 0 to 3: Speed Unit Selection
0: Reference unit/s
1: 10
n
reference unit/min
2: Percentage of rated speed (1 = 0.01%)
3: Percentage of rated speed (1 = 0.0001%)
Yes Yes
4.4.2 ( 4 )
Bits 4 to 7: Acceleration/Deceleration Degree Unit Selection
0: Reference unit/s
2
1: ms
Yes Yes
Bits 8 to B: Filter Type Selection
0: None
1: Exponential acceleration/deceleration filter
2: Moving average filter
Yes Yes
Bits C to F: Torque Unit Selection
0: Percentage of rated toque (1 = 0.01%)
1: Percentage of rated toque (1 = 0.0001%)
Yes Yes
OW04
Function Setting 2
Bits 0 to 3: Latch Detection Signal Selection
−−
4.4.2 ( 5 )
0: -
−−
1: -
−−
2: Phase-C pulse
Yes
3: /EXT1
Yes
4: /EXT2
Yes
5: /EXT3
Yes
Bits 4 to 7: External Positioning Signal Setting
−−
0:
−−
1:
−−
2: Phase-C pulse
Yes
3: /EXT1
Yes
4: /EXT2
Yes
5: /EXT3
Yes
Bits 8 to B: Reserved for system use.
−−
Bits C to F: Bank Selector
Yes
OW05
Function Setting 3
Bit 1: Phase Reference Creation Calculation Disable (0: Enabled/
1: Disabled)
Yes
4.4.2 ( 6 )
Bits 2 to A: Reserved for system use.
−−
Bit B: Zero Point Return Input Signal (0: OFF/1: ON)
Yes
Bits C to F: Reserved for system use.
−−
OW06
to
OW07
Reserved for system use.
−−
(cont’d)