9.1 Troubleshooting
9-9
9
Troubleshooting
9.1.2 INDEXER Module Alarm Displays and Troubleshooting
The INDEXER Module alarm list and the corresponding corrective actions are shown below.
∗1. The following function cannot be used with the SERVOPACK software version 0016 or earlier.
∗2. This function is available for the following software versions.
INDEXER module: Version 3 or later
SERVOPACK: Version 001B or later.
Serial
Command
Negative
Response
Panel
Display
Alarm Name Meaning Corrective Action
Servomotor
Stop
Method
Alarm
Reset
A.
SERVOPACK Alarm
Activation Alarm
A SERVOPACK alarm
occurred.
Refer to
9.1.1.
Refer to
9.1.1.
E12A A.AEF
Firmware Execution
Alarm
The firmware processing
time was too long.
Upgrade the firmware
version.
Reduce the number of
functions being used.
Gr.1 N/A
E13A A.AEF
Firmware Version
Unmatched
The SERVOPACK does
not supported this func-
tion, because the software
version do not match.
*1
Upgrade the SERVO-
PACK software ver-
sion.
Use the SERVOPACK
that supports the corre-
sponding function.
Use the SERVOPACK
with the function set
disabled.
Gr.1 N/A
E14A A.AEF
Parameter Checksum
Alarm
(Detected only when
control power supply is
turned ON.)
Incorrect or corrupted
parameters are stored in
EEPROM.
(This alarm can occur if
the control power supply
is turned OFF while the
parameters are being ini-
tialized or changed.)
Initialize the parame-
ters with the PRMINIT
command or FnB0B
*2
.
If the problem is not
solved, correct the
parameters.
Gr.1 N/A
E15A A.AEF
Parameter Version
Unmatched (Detected
only when the control
power supply is turned
ON.)
The combination of the
firmware version number
and the parameter version
number is wrong.
Change the firmware
version.
Change the parameter
version to match the
firmware version.
Gr.1 N/A
E16A A.AEF
Parameter Out-of-
range Alarm
(Detected only when
control power supply is
turned ON.)
The moving method is set
to a rotary method
(PnB20 = 1, 2, or 3), but
the home position set in
PnB25 exceeds the soft-
ware limits set in PnB21
and PnB23.
Correct the home position
setting (PnB25) or the
software limits (PnB21
and PnB23).
Gr.1 N/A
Function Name
SERVOPACK Software
Version Number
Related
Parameter
Remarks
0016 or earlier 0017 or later
Alarm Code Output
Signals
(/ALO1, /ALO2, /ALO3)
Not supported Supported PnB51
For the SERVOPACK whose soft-
ware version number is 0016 or
earlier, set PnB51 to 0 (PnB51 = 0).