6 Program Table
6.1.9 Response Times after Turning ON the /START-STOP Signal
6-12
6.1.9 Response Times after Turning ON the /START-STOP Signal
The response times after turning ON the /START-STOP signal are shown below.
Special Conditions
Program is stopped due to error.
Previous positioning was stopped.
Previous external latch is on standby.
Overtravel status exists.
Time Normal Under Special Conditions*
t
M
2 ms to 6 ms 2 ms to 16 ms
t
I
2 ms to 8 ms 2 ms to 14 ms
t
p
2 ms to 6 ms 2 ms to 10 ms
/START-STOP
t
M
/POUT0 to 7
Motor movement
/INPOSITION
t
I
t
P
Vue de la page 91