4 Wiring and Connection
4.1.1 Connecting to SGDV-FE1A SERVOPACK
4-2
4.1 System Configuration Diagram
Examples of basic servo system configurations are shown for each SERVOPACK type.
4.1.1 Connecting to SGDV-FE1A SERVOPACK
∗1. Use a 24-VDC power supply. (not included.)
∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to
Σ
-V Series User's Manual Design
and Maintenance Rotational Motor/Command Option Attachable Type (SIEP S800000 60).
Note: The connections and wiring of the power supply of the main circuit and that of the controls differ in accordance with
the SERVOPACK to be used. For details, refer to
Σ
-V Series User's Manual Design and Maintenance Rotational
Motor/Command Option Attachable Type (SIEP S800000 60).
Motor main circuit cable
Encoder cable
Battery case
DC brake power supply
*1
Magnetic contactor
Regenerative
resistor
*2
Noise filter
Molded-case
circuit breaker
(MCCB)
Magnetic contactor
I/O signal cable
SGDV-FE1A
SERVOPACK
INDEXER Module
SGMJV/SGMAV/SGMPS/SGMCS
Servomotor
Power supply:
Single-phase 100 VAC
R T
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is detected.
Used to eliminate
external noise from
the power line.
Used for a servomotor
with a brake.
Turns the servo
ON and OFF.
Install a surge
absorber.
Turns the brake power
supply ON and OFF.
Install a surge absorber.
(when an absolute
encoder is used.)
Personal computer
Connection cable
for personal computer
Digital operator
When not using the safety function,
use the SERVOPACK with the safety function
jumper connector (JZSP-CVH05-E,
provided as an accessory) inserted.
When using the safety function, insert a
connection cable specifically for the safety function.
Safety unit
Connection cable
for digital operator
100 VAC
Sequence I/O
signal cable
Host controller
Serial command
communications cable
Vue de la page 39