The following table shows the communications specifications of the CN12 connector.
RS-422 or RS-485
Host controller
Item Specifications
Interface
Full duplex (RS-422) or half duplex (RS-485)
(Selectable with parameter PnB00.)
Max. Number of Axes 16 axes
Total Cable Length RS-422/RS-485: 50 m max.
Bit Rate
9600, 19200, or 38400 bps
(Selectable with parameter PnB01. Factory setting: 9600 bps)
Synchronization Start-stop synchronization
Data Format
Start bits: 1 bit
Data bits: 7 bits, ASCII
Parity: 1 bit, even parity
Stop bits: 1 bit
Flow Control None
Shift Control None