9.1 Troubleshooting
9-11
9
Troubleshooting
∗2. This function is available for the following software versions.
INDEXER module: Version 3 or later
SERVOPACK: Version 001B or later.
∗4. These alarms can be reset, but it is possible that the zone signals (POUT0 to POUT7) will be output incorrectly.
When using the zone table, correct the zone table without resetting.
∗5. These alarms can be reset, but a Canceled JOG Speed Table Error (E46E) will occur the next time you attempt to start
JOG speed table operation, so JOG speed table operation will not be possible.
E1CA A.AEF
Zone Table Checksum
Alarm
(Detected only when
control power supply is
turned ON.)
The zone table stored in
flash memory was not
recorded properly.
(This alarm can occur if
the control power supply
is turned OFF while the
zone table is being saved
or initialized.)
Initialize the zone table
with the ZONEINIT
command or FnB07.
*2
If the problem is not
solved, correct the zone
table.
Gr.1
Available
*4
E1DA A.AEF
ZONE Table Version
Unmatched (Detected
only when the control
power supply is turned
ON.)
The combination of the
firmware version and the
ZONE table version is
wrong.
Change the firmware
version.
Change the ZONE
table version to match
the firmware version.
Gr.1
Available
*4
E1EA A.AEF
Zone Table Out-of-
range Alarm
(Detected only when
control power supply is
turned ON.)
A value set in the zone
table is not within the
allowed setting range.
Change the firmware
version.
Change the ZONE
table version to match
the firmware version.
Gr.1
Available
*4
E1FA A.AEF
JOG Speed Table
Checksum Alarm
(Detected only when
control power supply is
turned ON.)
The JOG speed table
stored in flash memory
was not recorded prop-
erly.
(This alarm can occur if
the control power supply
is turned OFF while the
JOG speed table is being
saved or initialized.)
Initialize the JOG
speed table with the
JSPDINIT command
or FnB08.
*2
If the problem is not
solved, correct the JOG
speed table.
Gr.1
Available
*5
E21A A.AEF
JOG Speed Table
Version Unmatched
(Detected only when
the control power
supply is turned ON.)
The combination of the
firmware version and the
JOG speed table version
is wrong
Change the firmware
version.
Change the JOG speed
table version to match
the firmware version.
Gr.1
Available
*5
E22A A.AEF
JOG Speed Table Out-
of-range Alarm
(Detected only when
control power supply is
turned ON.)
A value set in the JOG
speed table is not within
the allowed setting range.
Change the firmware
version.
Change the JOG speed
table version to match
the firmware version.
Gr.1
Available
*5
E23A A.AEF
Insufficient Registration
Distance Alarm
The registration distance
was shorter than the
deceleration distance
when the /RGRT signal
went ON to start registra-
tion operation. (The cur-
rent position will exceed
the position specified by
registration.)
Either increase the regis-
tration distance or reduce
the deceleration distance
(increase the decelera-
tion rate).
The registration distance
can be set by executing
the RDST command or
changing the RDST
parameter in the pro-
gram table.
The deceleration rate can
be changed by executing
the DEC command or
changing parameter
PnB2B.
Gr.1 Available
Serial
Command
Negative
Response
Panel
Display
Alarm Name Meaning Corrective Action
Servomotor
Stop
Method
Alarm
Reset