9.2 Warning Displays
9-13
9
Troubleshooting
Note 1. Set Pn001.3 =1 (Outputs both Alarm Codes and Warning Codes) to output warning codes.
2. If Pn008.2 = 1 (Does not detect warning) is selected, warnings other than the undervoltage warning (A.971) will
not be detected.
A.94A
Command Option Module IF
Data Setting Warning 1
This warning occurs when there is an error in a
parameter number sent to the SERVOPACK from
the host controller or command option module.
OFF
(open)
OFF
(open)
ON
(close)
A.94B
Command Option Module IF
Data Setting Warning 2
This warning occurs when out-of-range data is sent
to the SERVOPACK from the host controller or
command option module.
A.94C
Command Option Module IF
Data Setting Warning 3
This warning occurs when there is an error in the
parameter data sent to the SERVOPACK from the
host controller or command option module.
A.94D
Command Option Module IF
Data Setting Warning 4
This warning occurs when there is an error in the
data size sent to the SERVOPACK from the host
controller or command option module.
A.94E
Command Option Module IF
Data Setting Warning 5
This warning occurs when there is an error in the
latch mode settings sent to the SERVOPACK from
the host controller or command option module.
A.95A
Command Option Module IF
Command Warning 1
This warning occurs when the host controller or
command option module outputs an operating
command when the operation execution conditions
in the SERVOPACK have not been met.
ON
(close)
OFF
(open)
ON
(close)
A.95B
Command Option Module IF
Command Warning 2
This warning occurs when there is an error in the
command output from the command option mod-
ule to the SERVOPACK.
A.95D
Command Option Module IF
Command Warning 4
This warning occurs when a latch command is out-
put from the command option module to the SER-
VOPACK during latch operation.
A.95E
Command Option Module IF
Command Warning 5
This warning occurs when an unallowed command
combination is output to the SERVOPACK from
the command option module.
A.95F
Command Option Module IF
Command Warning 6
This warning occurs when there is an error in the
command output to the SERVOPACK from the
command option module.
A.960
Command Option Module IF
Communications Warning
This warning occurs when an error occurred in
communications between the SERVOPACK and
command option module.
OFF
(open)
ON
(close)
ON
(close)
A.971 Undervoltage
This warning occurs before the undervoltage alarm
(A.410) occurs. If the warning is ignored and oper-
ation continues, an undervoltage alarm may occur.
ON
(close)
ON
(close)
ON
(close)
A.
A9F Error
Some kind of
error has occurred at the INDEXER
Module.
Refer to 9.2.2 INDEXER Module Error Displays
and Troubleshooting.
ON
(close)
OFF
(open)
OFF
(open)
(cont’d)
Warning
Display
Warning Name Meaning
Warning Code Output
/ALO1 /ALO2 /ALO3
Vue de la page 184