9.3 Troubleshooting Malfunction Based on Operation and Conditions
9-25
9
Troubleshooting
Linear
Servomotor
Moves
Without
Reference
Input
A SERVOPACK fault occurred. Replace the SERVOPACK.
Linear scale counting up direction
and motor moving coil forward
direction do not agree.
Check the directions.
Change the setting of Pn080.1
(Motor Phase Selection).
Match the linear scale direction and
moving coil direction.
Polarity detection is not performed
correctly.
Check if the value of Un004 (Elec-
tric Angle 2, angle from polarity
origin) at an arbitrary position is
between ±10 degrees.
Correct the settings for the polarity
detection related parameter.
DB (dynamic
brake) Does Not
Operate
Improper setting of parameter
Pn001.0
Check the setting of parameter
Pn001.0.
Correct the setting of parameter
Pn001.0.
DB resistor disconnected
Check if excessive mass, motor
overspeed, or DB frequent activa-
tion has occurred.
Replace the SERVOPACK, and
reconsider the load.
DB drive circuit fault
DB circuit parts are faulty.
Replace the SERVOPACK.
Abnormal Noise
from Linear
Servomotor
The linear servomotor largely
vibrated during execution of tuning-
less function (factory setting).
Check the motor speed waveform.
Reduce the load so that the mass
ratio becomes within the allowable
value, or increase the load level or
lower the rigidity level for the tun-
ing-less level setting (Fn200).
Mounting not secured
Check if there are any loosen
mounting screws.
Tighten the mounting screws.
Vibration source on the driven
machine
Check the machine movable section
for foreign matter, damage or defor-
mity.
Contact the machine manufacturer.
Noise interference due to incorrect
I/O signal cable specifications
The specifications of I/O signal
cables must be:
Shielded twisted-pair or shielded
multi-core twisted-pair wire with
core 0.12 mm
2
min. and tinned
annealed copper twisted wire.
Use the specified I/O signal cables.
Noise interference due to long dis-
tance of I/O signal cable
Check the I/O signal cable length.
Shorten the I/O signal cable length
to 3 m or less.
Noise interference due to incorrect
specifications of linear scale con-
nection cables.
The specifications of cable for con-
necting serial converter unit must
be:
Shielded twisted-pair or shielded
multi-core twisted-pair wire with
core 0.12 mm
2
min. and tinned
annealed copper twisted wire.
Use the specified linear scale con-
nection cables.
Noise interference because the lin-
ear scale connection cables is too
long
Check the length of the linear scale
connection cables.
The maximum length of linear scale
connection cables:
20 m for the cable for connecting a
serial converter unit
15 m for the cable for connecting a
linear scale/hall sensor
(cont’d)
Problem Probable Cause Investigative Actions Corrective Actions