YASKAWA SERVO Manuel d'utilisateur Page 206

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 239
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 205
10.1 Parameter List for INDEXER Module
10-5
10
Appendix
PnB0D
/SEL7 0 to 3 0 After restart 6.1.2
PnB0E
/S-ON 0 to 3 0 After restart 5.3.1
PnB0F
P-OT 0 to 3 0 After restart 5.3.2
PnB10
N-OT 0 to 3 0 After restart 5.3.2
PnB11
/DEC 0 to 3 0 After restart 6.4.2
PnB12
/RGRT 0 to 3 0 After restart 6.2.2
(cont’d)
Parameter
No.
Name Setting Range
Setting
Unit
Factory
Setting
When
Enabled
Reference
Setting Meaning
0 When input signal is ON (close), program table selection signal /SEL7 becomes active.
1 When input signal is OFF (open), program table selection signal /SEL7 becomes active.
2 Program table selection signal /SEL7 is always active.
3 Program table selection signal /SEL7 is always inactive.
Setting Meaning
0 When input signal is ON (close), servomotor power is ON. Servomotor can be operated.
1 When input signal is OFF (open), servomotor power is ON. Servomotor can be operated.
2 Always servo ON
3 Always servo OFF
Setting Meaning
0 When input signal is OFF (open), forward run is prohibited (forward overtravel).
1 When input signal is ON (close), forward run is prohibited (forward overtravel).
2 Forward run is always prohibited (forward overtravel).
3 Forward run is always enabled. (P-OT signal is not used.)
Setting Meaning
0 When input signal is OFF (open), reverse run is prohibited (reverse overtravel).
1 When input signal is ON (close), reverse run is prohibited (reverse overtravel).
2 Reverse run is always prohibited (reverse overtravel).
3 Reverse run is always enabled. (N-OT signal is not used.)
Setting Meaning
0 Starts deceleration in homing when input signal is ON (close).
1 Starts deceleration in homing when input signal is OFF (open).
2 Sets homing limit switch always ON.
3 Sets homing limit switch always OFF.
Setting Meaning
0 Starts registration by switching input signal from OFF (open) to ON (close).
1 Starts registration by switching input signal from ON (close) to OFF (open).
2, 3 Does not start registration.
Vue de la page 205
1 2 ... 201 202 203 204 205 206 207 208 209 210 211 ... 238 239

Commentaires sur ces manuels