YASKAWA SERVO Manuel d'utilisateur Page 226

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 239
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 225
10.2 Parameter List for Command Option Attachable Type SERVOPACKs
10-25
10
Appendix
Pn586
*2
Motor Running Air-cooling Ratio 0 to 100
1%/
maxvel
0 Immediately Setup
Pn587
*2
Polarity Detection for Absolute Scale Selection 0000 to 0001 0000 Immediately Setup
Pn600
Regenerative Resistor Capacity
3
Depends on
SERVOPACK
Capacity
4
10 W 0 Immediately Setup
Pn601 Reserved (Do not change.) 0
Pn800 to
Pn95F
Reserved (Do not change.) 0
∗2. Parameter exclusive for linear servomotors
∗3. Normally set to “0.” When using an external regenerative resistor, set the capacity (W) of the regenerative resistor.
∗4. The upper limit is the maximum output capacity (W) of the SERVOPACK.
(cont’d)
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Polarity Detection for Absolute Scale Selection
0
1
Reserved (Do not change.)
Does not detect polarity.
Detects polarity.
Reserved (Do not change.)
Reserved (Do not change.)